Advanced Home Automation functionsAdvanced Home Automation functions
Besides the Plug&Play modules a large number of built-in switches, sun blind switches, remote
controls and special modules are available. With the addition of these modules you can control
nearly everything that is electrically powered in your home via your security systems. See
www.ehem.se for more information.
Checking the status of the security system
Set a X10 module to adress B4 (=HC+1, UC=4). This Home Automation module is now automatically switched on
as soon as the security system is activated. When the system is disarmed, the module is also switched off.
Example: you can connect a table lamp to this X10 module. If the system is activated, this lamp is always turned
on. This means you can instantly see if the system is activated when you are outside.
Installing an extra siren Ph7208
Set the siren Ph7208 to adress A1 (=HC, UC=1). To avoid false alarms, the system waits 20 seconds after
triggering the alarm before the siren is activated. The siren will give a piercing two-tone signal for 4 minutes. After
these 4 minutes the siren is automatically switched off (or sooner if the alarm is switched off)
ATTENTION: When using a security system, the extra sirens will always work in case of an alarm, even when the
system is set to silent alarm. The Siren Ph7208 is meant for indoor use and can be plugged into any wall socket.
Universell extra sirén
You can also add sirens and warning lights that are not part of the range. Please use a separately available Ad10,
Aw12 or the Am12. Set this module to adress B6 =(HC+1, UC=6). The module is switched on in case of an alarm
and switched off after 4 minutes.Power for the Sirén is 220 V 50Hz, if not use module UM7206.
,
All Home Automation functions at a glance
Function
Comfort lighting
Exit delay
Alarm lighting
Statusindicator
X10-siren
Universalsiren
H.A Automation
Thermostats
You can switch your lighting using the
buttons Lights ON and Lights OFF on
your key chain remote control.
Lights are awitched on during the exit
delay.
In case of an alarm, the lights will flash
during 4 minutes and then remain on.
The lights are switched on when the
system is set to Arm Away.
Ph7208 extra 110 dB sirén.
Connect an own siren to a AM12 or
AD10 module.
H.A functions in respond to sensor
(27-32) when in ARMED mode.
Thermostats H.A addresses
Power failure
After 15 minutes will the alarm be
trigged and a phonemessege will be
sent “power failure”.
A1 och A2 (HC, UC=1 + UC=2)
A1 och A2 (HC, UC=1 + UC=2)
A1 och A2 (HC, UC=1 + UC=2)
B4 (HC+1, UC=4)
A1 och A2 (HC, UC=1 + UC=2)
B6 (HC+1, UC=6)
B7-B12
(HC+1, UC=7-12).
B13-B16
(=HC+1, UC=13-16)
This table uses the unchanged
settings (House Code + Unit Code)
for the basic console adress.
The default base adress ia A1.
14